Skip to main content

React Quickly: Trading ESE

Great performance and high turnover frequency: Trading ESE allows you to react quickly to marketplace changes and balance peak load fluctuations. Use the practical standard configuration or easily configure your own customized product.

The conversion of annual service prices into service prices for capacity rights during the year as well as for the proper determination of network charges ("REGENT") applies accordingly to the regulations of the Bundesnetzagentur. 

According to this, the entry and exit fees by the upstream network operator to storage facilities, which are connected to more than one market area are, shall be provided with a discount of 75% as far as VNG Gasspeicher GmbH maintains separate storage accounts for its customers (discounted and non-discounted storage accounts). This proves that storage does not serve for avoiding the transport between market areas. VNG Gasspeicher GmbH offers such an account model for its Etzel storage facility on the basis of this regulation, which comes into force on 101/01/2020.

In contrast to the previous regulation ("BEATE"), gas can only be transferred between two discounted accounts or two non-discounted accounts within the same market area. The rebooking fee has been abolished.

Further information can be found in the product overview under FAQ and in the "Additional conditions for the cross-market area use of the Etzel storage facility" (attached to the model contract).

 

Configure in easystore

 

  
Market area

THE

Storage

Etzel

Turnover duration

102 - 314 Days

Characteristic curve restrictions

yes

Interruptibility

firm

Minimum booking amount

2.5 GWh

Transport

Booking and nomination by storage customer

Lead time for renomination

2.0 h

Implementation period

Non binding booking request:

Ten (10) working days

Online bookind:

Two (2) working days

Transfer of ownership

no

Physical storage

yes

Transfer points

 

 

StorageMarket areaAdjacent network operatorGas transfer point
Etzel

 

THE
 

Gasunie Deutschland Transport Services GmbHUGS Etzel ESE
Open Grid Europe GmbHEtzel (Speicher ESE),
Bitzenlander Weg 3,
Speicher

 

easystore configuration boundaries per 1 GWh

 

Minimum

Standard

Maximum

 Injection rate

MWh/h

 

0.60

0.87

1.10

 Withdrawal rate

MWh/h

 

0.80

1.10

1.40

 Injection duration

Days

 

81

60

50

 Withdrawal duration

Days

 

54

40

33

 Transfer duration

Days

 

135

100

83

Additional services     
 Combination with other products

firm

 

Day-Ahead | Within-Day 
Trading 
Add on Early Injection | Add on Late
Withdrawal
Add on WGV | WR | IR

 

interruptible

 

Micro

 Gas transfer

On request (charges as per fee schedule; free of charge for connection contracts)

 (Partial) capacity transfer

 

 

yes

  
Sample Contract Trading ESE

Link

GTC

Link

Operating Manual (Flansch)

Link

Fee Schedule

Link

 

Image
ESL Chart ESE
Injection characteristic curve
IR100%MWh/h0.87
IRRedMWh/h0.39
WGABIGWh0.44
WGAB100%GWh1.00
Withdrawal characteristic curve
WR100%MWh/h1.10
WRredMWh/h0.64
WGABWGWh0.21
WGAB100%GWh1.00

* These are the characteristics of the default configuration example of 1 GWh.

Image
ASL Chart ESE

 

 

 

 

 

 

 

 

 

 

 

Do you have questions or  
need help deciding?

 

Free Capacities   Contact us   Configure your Product

Up North: Trading JEM

Great performance and high turnover frequency: Trading JEM allows also to react quickly to marketplace changes and balance peak load fluctuations. Use the practical standard configuration or easily configure your own customized product.


 

  
Market area

THE | TTF

Storage

Jemgum

Turnover duration

892 - 153 Days

Characteristic curve restrictions

yes

Interruptibility

firm

Minimum booking amount

2.5 GWh

Transport

Booking and nomination by storage customer

Lead time for renomination

2.0 h

Implementation period

Non binding booking request:

Ten (10) working days

Online bookind:

Two (2) working days

Transfer of ownership

no

Physical storage

yes

Transfer points

 

 

StorageMarket areaAdjacent network operatorGas transfer point
Jemgum

 

THE
 

GASCADE Gastransport GmbHJemhim I
TTFGasunie Transport Services B.V.Oude Statenzijl
(astora Jemgum)
easystore configuration boundaries per 1 GWh

 

Minimum

Standard

Maximum

 Injection rate

MWh/h

 

0.50

0.60

0.80

 Withdrawal rate

MWh/h

 

0.60

0.90

1.20

 Injection duration

Days

 

83

69

53

 Withdrawal duration

Days

 

70

47

36

 Transfer duration

Days

 

153

116

89

Additional services     
 Combination with other products

firm

 

Day-Ahead | Within-Day 
Trading 
Add on Early Injection | Add on Late
Withdrawal
Add on WGV | WR | IR

 

interruptible

 

Micro

 Gas transfer

On request (charges as per fee schedule; free of charge for connection contracts)

 (Partial) capacity transfer

 

 

yes

  
Sample Contract Trading JEM

Link

GTC

Link

Operating Manual (Flange)

Link

Fee Schedule

Link

Injection characteristic curve
IR100%MWh/h0.60
WGAB100%GWh1.00
Withdrawal characteristic curve
WR100%MWh/h0.90
WRredMWh/h0.63
WGABWGWh0.05
WGAB100%GWh1.00

* These are the characteristics of the default configuration example of 1 GWh.

Image
ASL Chart JEM

 

 

 

 

 

 

 

 

 

 

Do you have questions or  
need help deciding?

 

Free Capacities   Contact us   Configure your Product

Directly in VGS Storage Hub: Trading VSH

The flange product "Trading" is characterized by high performance and turnover frequency. It allows you to react quickly to marketplace changes so that you can balance peak load fluctuations. Benefit from our storage area by an even higher utilization probability of your booked capacities. We optimize our storage facilities and the associated maintenance measures.

Use the standard Trading configuration or easily configure your own customized product.

 

Configure in easystore

 

  
Market area

THE

Storage

VGS Storage Hub

Turnover duration

175 Days

Characteristic curve restrictions

yes

Minimum level

no

Interruptibility

firm

Minimum booking amount

2.5 GWh

Transport

Booking and nomination by storage customer

Lead time for renomination

2.0 h

Implementation period

Non binding booking request:

Ten (10) working days

Online booking:

Two (2) working days

Transfer of ownership

no

Physical storage

yes

Transfer point

 

 

StorageMarket areaAdjacent network operatorGas transfer point
VGS Storage HubTHEONTRAS Gastransport GmbHVGS Storage Hub
easystore configuration boundaries per 1 GWh

 

Minimum

Standard

Maximum

 Injection rate

MWh/h

 

0.35

0.60

1.20

 Withdrawal rate

MWh/h

 

0.30

0.82

1.50

 Injection duration

Days

 

174

102

51

 Withdrawal duration

Days

 

178

73

45

 Transfer duration

Days

 

352

175

96

Additional services     
 Combination with other products

firm

 

Day-Ahead | Within-Day
Trading
Add on Early Injection | Add on Late
Withdrawal
Add on WGV | WR | IR

 

interruptible

 

Pure | Micro

 Gas transfer

On request (charges as per fee schedule; free of charge for connection contracts)

 (partial) capacity transfer

 

 

yes

  
Sample Contract Trading VSH

Link

GTC

Link

Operating Manual (Flange)

Link

Fee Schedule

Link

Image
ESL Chart VSH
Injection characteristic curve (1 GWh)
IR100%MWh/h0.60
IRred1MWh/h0.44
IRred2MWh/h0.32
IRred3MWh/h0.15
WGAB1GWh0.47
WGAB2GWh0.65
WGAB3GWh0.95
WGAB100%GWh1.00
Withdrawal characteristic curve(1 GWh)
WR100%MWh/h0.82
WRredMWh/h0.19
WGABW1GWh0.06
WGABW2GWh0.31
WGAB100%GWh1.00
Image
ASL Chart VSH

 

 

 

 

 

 

Do you have questions or  
need help deciding?

 

Free Capacities   Contact us   Configure your Product

Trading+Gas 

Act immediately on the market - with our "Trading + Gas" product, you can start withdrawing gas at the beginning of the service period.

We provide you with a gas-filled storage in the THE market area. Use the gas for your needs and store it again at a later date. At the end of the contract, you hand the filled storage back to us. 

Market area

THE

Storage

VGS Storage Hub

Turnover duration

164 Days

Characteristic curve restrictions

yes

Minimum level

no

Interruptibility

firm

Minimum booking amount

2.5 GWh

Transport

Booking and nomination by storage customer

Lead time for renomination

2.0 h

Implementation period

Two (2) working days

Transfer of ownership

yes

Physical storage

yes

Transfer point

 

 

StorageMarket areaAdjacent network operatorGas transfer point
VGS Storage HubTHEONTRAS Gastransport GmbHVGS Storage Hub
easystore configuration boundaries per 1 GWh 

Standard

 Injection rate

MWh/h

 

0.60

 Withdrawal rate

MWh/h

 

0.82

 Injection duration

Days

 

91

 Withdrawal duration

Days

 

73

 Transfer duration

Days

 

164

 Configuration

 

 

on request

Additional services   
 Combination with other products

 

no

 Gas transfer

    yes, but only for the contract Trading + Gas (charges as
per Fee schedule, free of charge for connection contracts)

 (partial) capacity transfer

 

yes

  
Sample Contract

Link

GTC

Link

Operating Manual

Link

Fee Schedule

Link

Image
ESL Chart VSH
Injection characteristic curve (1 GWh)
IR100%MWh/h0.60
IRred1MWh/h0.44
IRred2MWh/h0.32
IRred3MWh/h0.15
WGAB1GWh0.47
WGAB2GWh0.65
WGAB3GWh0.95
WGAB100%GWh1.00
Withdrawal characteristic curve(1 GWh)
WR100%MWh/h0.82
WRredMWh/h0.19
WGAB1GWh0.06
WGAB2GWh0.31
WGAB100%GWh1.00
Image
ASL Chart VSH

 

 

 

 

 

 

Do you have questions or  
need help deciding?

 

Free Capacities   Contact us   Configure your Product

Flat? Trading Flat!

No characteristic curve restriction and a turnover period of only 60 days on a firm basis - this is what our product Trading Flat offers. Use the conditions of transport on a monthly basis and react quickly to market changes.

The product is also available on VTP - Hub Trading Flat.

You can book the product in Easystore easily. Do you need the capacity the next day? No problem. With a lead time of 16 hours you can book your desired capacity day-ahead. The fee calculation is dynamic and the current market conditions are adapted. Configure your product in Easystore and in the configuration overview you will see the corresponding fee. An extended registration for online booking is necessary.

Market area

THE

Storage

VGS Storage Hub

Turnover duration

60 Days

Characteristic curve restrictions

no

Interruptibility

firm

Minimum booking amound

2.5 Gwh

Transport

Booking and nomination by storage customer

Lead time for renomination

2.0 h

Implementation period

Online booking:

Sixteen(16) hours

Transfer of ownership

no

Physical storage

yes

Transfer points

 

 

StorageMarket areaAdjacent network operatorGas transfer point
VGS Storage HubTHEONTRAS Gastransport GmbHVGS Storage Hub

 

easystore configuration boundaries per 1 GWh  

Standard

 Injection rate

MWh/h

  

1.39

 Withdrawal rate

MWh/h

 

 

1.39

 Injection duration

Days

  

30

 Withdrawal duration

Days

  

30

 Transfer duration

Days

  

60

Contract term    
 Start 

 

 

day-ahead

 Duration 

 

Booking before 01/12/20xx: Duration until
01/04/20xx+1
Booking after 01/12/20xx: Duration until
01/04/20xx+2

Additional services 

 

 

 

 Combination with other products

firm

Day-Ahead | Within-Day
| Trading |
Add on Early Injection | Add
on Late Withdrawal | Trading,
Hub Trading on request

 

interruptible

 

Pure | Micro (on request)

 Gas transfer

On request (charges as per fee schedule; free of
charge for connection contracts)

 Capacity overrun

yes

 (Partial) capacity transfer

 

 

yes

  
Sample Contract Trading Flat

Link

GTC

Link

Operating Manual (Flange)

Link

Fee Schedule

Link

Image
ESL Trading Flat
Injection characteristic curve(1 GWh)
IR100%MWh/h1.39
WGAB100%MWh/h1.00
Ausspeicherkennlinie (1 GWh)
IR100%MWh/h1.39
WGAB100%MWh/h1.00

* These are the characteristics of the default configuration example of 1 GWh.

Image
ASL Trading Flat

 

 

 

 

 

 

 

 

 

 

 

Do you have questions or  
need help deciding?

 

Free Capacities   Contact us   Configure your Product

Trading VSH green

Would you like to make an environmentally friendly contribution to the storage of gas? With "Trading VSH green", we cover the energy requirements for the injection and withdrawal of gas into and from the underground storage facilities in an ecologically responisble form using energy from 100 percent bio natural gas. Thus the green product differs only in the amount of the variable fee. You do not have to do without the well-known performance and flexibility of the Trading VSH product. 

Market area

THE

Storage

VGS Storage Hub

Turnover duration

175 Days

Characteristic curve restrictions

yes

Minimum level

no

Interruptibility

firm

Minimum booking amount

2.5 GWh

Transport

Booking and nomination by storage customer

Lead time for renomination

2.0 h

Implementation period

3 months

Transfer of ownership

no

Physical storage

yes

Transfer point 

 

StorageMarket areaAdjacent network operatorGas transfer point
VGS Storage HubTHEONTRAS Gastransport GmbHVGS Storage Hub


 

 

easystore configuration boundaries per 1 GWh MinimumStandardMaximum
 Injection rateMWh/h 0.350.601.20
 Withdrawal rateMWh/h 0.300.821.50
 Injection durationDays 17410251
 Withdrawal durationDays 1787345
 Transfer durationDays 35217596
Additional services     
 Combination with other productsfirm Day-Ahead | Within-Day
Trading 
Add on Early Injection | Add on Late Withdrawal
Add on WGV | WR | IR
 interruptible Pure | Micro
 Gas transfer

On request (charges as per fee schedule; free of charge for connection contracts)

 (Partial) capacity transfer  yes

Documents

 
Sample Contract Trading VSH green

Link

GTC

Link

Operating Manual (Flange)

Link

0Fee Schedule

Link

Image
ESL Chart VSH
Injection characteristic curve(1 GWh)
IR100%MWh/h0.60
IRred1MWh/h0.44
IRred2MWh/h0.32
IRred3MWh/h0.15
WGAB1GWh0.47
WGAB2GWh0.65
WGAB3GWh0.95
WGAB100%GWh1.00
Withdrawal characteristic curve(1 GWh)
WR100%MWh/h0.82
WRredMWh/h0.19
WGABW1GWh0.06
WGABW2GWh0.31
WGAB100%GWh1.00
Image
ASL Chart VSH

 

 

 

 

 

 

Do you have questions or  
need help deciding?

 

Free Capacities   Contact us   Configure your Product